自复保险丝自恢复保险丝
JK-mSMD系列自复保险丝
Electrical characteristics(25℃)
Model
V max
I max
I hold
I trip
Time to trip
R25
@25°C
@25°C
Current
Time
R min
R1max
(V dc)
(A)
(A)
(Sec)
(W)
(W)
JK-mSMD010
30.0
100
0.10
0.30
0.5
1.50
0.750
15.000
JK-mSMD010-60
60.0
JK-mSMD014-33
33.0
0.14
0.34
1.5
0.15
0.650
6.000
JK-mSMD014
JK-mSMD020
0.20
0.40
8.0
0.02
0.350
5.000
JK-mSMD030
0.60
0.10
0.250
3.000
JK-mSMD050
15.0
0.50
1.00
0.150
1.000
JK-mSMD050-24
24.0
JK-mSMD050-30
JK-mSMD075
13.2
0.75
1.50
0.20
0.090
0.450
JK-mSMD075-24
24
JK-mSMD075-33
33
JK-mSMD110
8.0
1.10
2.20
0.30
0.050
0.250
JK-mSMD110-16
16.0
JK-mSMD110-24
JK-mSMD110-33
JK-mSMD125-8
1.25
2.50
0.40
0.200
JK-mSMD125
JK-mSMD150
3.00
0.50
0.040
0.160
JK-mSMD150-16
JK-mSMD150-24
JK-mSMD160
1.60
2.80
1.00
0.030
0.130
JK-mSMD200
2.00
4.00
2.00
0.020
0.100
JK-mSMD200-12
12.0
JK-mSMD200-16
JK-mSMD260
2.60
5.00
2.50
0.015
0.050
JK-mSMD260-12
0.060
JK-mSMD260-16
JK-mSMD300
4.00
0.012
0.040
I hold=Hold current: maximum current device will not trip in 25°C still air.
I trip =Trip current: minimum current at which the device will always trip in 25°Cstill air.
V max =Maximum operating voltage device can withstand without damage at rated current (Imax).
Imax =Maximum fault current device can withstand without damage at rated voltage (V max).
Pd=Maximum power dissipation when device is in the tripped state in 25°C still air environment at rated voltage.
R min/max=Minimum/Maximum device resistance prior to tripping at 25°C.
R1max=Maximum device resistance is measured one hour post reflow.
联系方式
- 地址:深圳 深圳市罗湖区文锦中路东侧锦绣大厦A栋6A
- 邮编:518000
- 电话:86-0755-25830231
- 销售:陈先生
- 手机:15013802729
- 传真:0755-2547 0703
- QQ:741449484
- Email:lu_homestar@126.com